Description
Measures and Sources various parameters
Display : 50000 Counts Dual, Backlit Display
Source and Measured values can be seen on the
same screen together
Source and Measurement can be done at the same time
Confirms to IEC 61010
Data Hold Function to freeze the displayed data
Measures
DC Voltage
0 – 50mV / 500mV /
5V / 50V DC
Accuracy ±0.02%
DC Current 0 – 50mA
Accuracy ±0.02%
Resistance 0 – 500 / 5kW
Accuracy ±0.05%
Frequency 0 – 500 / 5k / 50kHz
Accuracy ±2digits
Temperature through
PT-100 Sensor
-200°C to 800°C
Accuracy ±0.5°C
Temperature through
PT-200 Sensor
-200°C to 630°C
Accuracy ±0.8°C
Temperature through
PT-500 Sensor
-200°C to 630°C
Accuracy ±0.4°C
Temperature through
PT-1000 Sensor
-200°C to 630°C
Accuracy ±0.3°C
Temperature through
Cu-10 Sensor
-100°C to 260°C
Accuracy ±1.8°C
Temperature through
Cu-50 Sensor
-50°C to 150°C
Accuracy ±0.7°C
Temperature through
R type Sensor
0°C to 1767°C
Accuracy ±1.5°C
Temperature through
S type Sensor
0°C to 1767°C
Accuracy ±1.5°C
Temperature through
B type Sensor
600°C to 1820°C
Accuracy ±1.4°C
Temperature through
E type Sensor
-50°C to 1000°C
Accuracy ±0. 9°C
Temperature through
K type Sensor
-100°C to 1372°C
Accuracy ±0.8°C
Temperature through
J type Sensor
-60°C to 1200°C
Accracy ±0. 7°C
Temperature through
T type Sensor
-100°C to 400°C
Accuracy ±0. 7°C
Temperature through
N type Sensor
-200°C to 1300°C
Accuracy ±0.9°C
Continuity Test Facility
Sources
DC Voltage 0 – 100m / 1 / 10V
Accuracy ±0.02%
DC Current 0 – 20mA
Accuracy ±0.02%
Analog Transducer -20mA
Accuracy ±0.02%
Resistance 0 – 400 / 4k / 40kW
Accuracy ±0.02%
Frequency
0 – 100 / 1k / 10k /
100kHz
Accuracy ±2Counts
Pulse 0 – 100 / 1k / 10kHz
Accuracy ±2Counts
Loop Power 24V
Accuracy ±10%
Switch
0 – 100 / 1k / 10k /
100kHz
Accuracy ±2%
Temperature output for
Pt-100 Sensor
-200°C to 800°C
Accuracy ±0.3°C
Temperature output for
Pt-200 Sensor
-200°C to 630°C
Accuracy ±0.2°C
Temperature output for
Pt-500 Sensor
-200°C to 630°C
Accuracy ±0.2°C
Temperature output for
Pt-1000 Sensor
-200°C to 630°C
Accuracy ±0.2°C
Temperature output for
Cu-10 Sensor
-100°C to 260°C
Accuracy ±2°C
Temperature output for
Cu-50 Sensor
-50°C to 150°C
Accuracy ±0.6°C
Temperature output for
R type Sensor
0°C to 1767°C
Accuracy ±1.2°C
Temperature output for
S type Sensor
0°C to 1767°C
Accuracy ±1.2°C
Temperature output for
B type Sensor
600°C to 1820°C
Accuracy ±1.1°C
Temperature output for
E type Sensor
-200°C to 1000°C
Accuracy ±0.4°C
Temperature output for
K type Sensor
-200°C to 1372°C
Accuracy ±0.5°C
Temperature output for
J type Sensor
-200°C to 1200°C
Accuracy ±0.5°C
Temperature output for
T type Sensor
-250°C to 400°C
Accuracy ±0.6°C
Temperature output for
N type Sensor
-200°C to 1300°C
Accuracy ±0.7°C
Pressure
(Source + Measurement)
2.49kPa ~ 70MPa
(Depending on the pressure
module used)
Reviews
There are no reviews yet.